Structural
- Architectural skin is load bearing for precast floor members
- Architectural skin provides lateral resistance as moment frame in north-south direction of the building
- Structural design minimized number of precast pieces needed
- Slab and beam composite concrete system
- Floor members designed as continuous spans to reduce deflections and structure depth
- Slab and beam system provides equivalent of 6-ft-on-center, skip joist cast-in-place system with a structure depth of 21 in. at the joists
- 1,349 total precast pieces, including wall panels, columns, tri-slabs, flat-slabs and rectangular beams